DOI: 10.5176/2301-394X_ACE17.74

Authors: Dušan Katunský, Miloslav Bagoňa, Martin Lopušniak and Miroslava Špaková

Abstract:

Window sill of brick walls is one of the most critical places in a connection of two envelope types objectively. If there are the transparent and opaque parts present together, the connection is much more complicated. Different behavior of the construction materials in dynamic boundary conditions causes deformations of thermal field of the window sill detail. Numerical thermal field analysis verified by the experimental measurement in experimental outdoor chambers is used for recognize the real heat-air-moisture behavior in the various constructions.

Keywords: Thermal field; numerical analysis; measuring; window sill; experimental chamber